NCNR NG7-SANS Instrument Schedule J. Barker Tel: (301)975-6732 Fax: (301)921-9847, E-mail: barker@nist.gov Instrument Tel: (301)975-5082 Changeover time: 9:30 a.m. -------------------------------------------------------------------------------- Start Num UniqID Date Days Users S-No Experiments Equip Contact ----- ----- ------------------ ------- ------------------------ ----- -------- Mar 1 1 SANS Scientists 15330 Instrument calibration Krzywon NIST Mar 2 2 D Gilbert+J 23330 Skyrmion Lattice HM2 Bleuel Borchers (NCNR) S36-18 Structure in Doped SeOCuO crystals Mar 4 1 D Gilbert+J 24757 Observation of Skyrmion HM2 Bleuel Borchers (NCNR) NIST Liquid Mar 5 2 K. Weigandt, J. 247879 Understanding the Rheo Weigandt Weston NIST alignment peak signature in WLMs Mar 7 4 M. Bleuel, K. 24481 Study of the magnetic HM2 Bleuel Krycka, N. Butch NIST interactions of NiFe inclusions in Cu Mar 11 1 M. Bleuel 22495 Test of MIEZE spin HM2 Bleuel NIST flippers Mar 12 2 M. Foster, J. 24449 Elucidating Structure 7HB Teixeira Meyerhofer, W. Zhao NIST-P Around Polymer Nanoparticles Mar 14 2 M Dadmun+S Rinehart 24135 Pore Structure of 10CB Jensen (UTN)+M Meador+R S38-29 Polyimide Aerogels for Viggiano (NASA) Battery Separators Mar 16 3 M. Bleuel, M. 20816 TISANS sample environment SCM/ Bleuel Eskildson NIST tests up to 1kHz OC Mar 19 2 J Riley+P Butler 24471 Structure and electrical rheo Jensen/Butler (NCNR) S37-129 properties of G2 bicontinuous Mar 21 2 B Olsen+D Mai+YJ 24025 Structure of Protein- 10CB Krueger Yang (MIT) S37-07 Polymer Materials for Selective Mar 23 3 K Krycka+J Borchers 24495 Influence of HM1, Krycka (NIST)+S Majetich S37-134 magnetocrystalline CCR, (CMU) anisotropy on exchange Mar 26 1 M. Calabrese, B. 24025 Structure of Protein- 10CB Liu Olsen, D. Mai, Y.J. NIST-P Polymer Materials for Yang Selective Bioseparations Mar 27 1 S. Rogers 24943 Shape controlled 10CB Kelley NIST bottlebrushes Mar 28 2 S Winslow+W 24028 Quantification of Ligand 10CB Liu Tisdale+J Swan S37-08 Shell Structure in (MIT) Colloidal PbS Mar 30 2 S. Teixeira, D. 24855 Non-native Protein 9CB Teixeira Gomes, J. Berger, NIST Aggregation Under Common C. Roberts Stress Conditions Apr 1 2 J. Nayem, 24881 Investigating Temperature 9CB Liu Y.(Summer) Tein, Y. NIST Dependence of Standard Liu NIST Monoclonal Antibody Apr 3 3 C. Leighton, S. El- 24512 Probing Ferromagnetic 9T Barker Khatib UMN Order in YTiO3 Single Crystals Apr 6 2 K. Weigandt, J. 247879 Understanding the Rheo Weigandt Weston NIST alignment peak signature in WLMs -------------------------------------------------------------------------------- Equipment: 9P:9-Position ambient sample changer; 10CB: 10 Position sample changer (-10 to 100 C); VF: Vacuum Furnace; 7H: 7 Position Heating Block (up to 200 deg C); 7HB: 7 Position Heating Block with BN (up to 300 deg C) HM1:Horizontal High-Field Electromagnet (2 Tesla); HM2:Horizontal Low-Field Electromagnet (0.5 Tesla); DI: Closed Cycle, Displex, refrigerator (10K to 330K); MSC: Minnesota Sliding Plate Shear Cell; BSC: Boulder Couette Flow Shear Cell; SE: Special Environment; NPC: NIST Pressure Cell; SCM: Superconducting Magnet(7 Tesla); 2H: 2 Position Heating Block; VR: Vertical Rotation Stage; Contacts: Paul Butler (x2028), John Barker (x6732), John Barker (x6732) Jeff Krzywon (x6650), Cedric Gagnon (x2020), Michael Zhang (x5513) Yimin Mao (x6017), Yun Liu (x6235), Markus Bleuel (x5165), Susana Teixeira (x4404)