DCS Status

========STATUS========
Current time: 21-May-2013 11:26:01
Collimator oscillating
Local shutter is closed
Monitoring in progress : /usr/local/dcs/log/hdwmon_201304.log
!Threshholds       VG1       VG2       VG3       VG4      CTMP      GTMP
 High              1.5       1.5       1.5       1.5      38.0      30.0
 Low               1.0       1.0       1.0       1.0      35.0      28.0
A 21-May-2013 11:19:23   VG:21-May-2013 11:19:20    CH:21-May-2013 11:16:43
B   Absolute_Time     VG1    VG2    VG3    VG4 TLCAB TRCAB  T_GH MSPEED df/dt
C      380319.323     0.1    0.1    0.1    0.1  22.2  25.8  22.8  20000  1.00
D OSENS1 OSENS2 OSENS3 OSENS4 THERM1 THERM2 THERM3 THERM4
E   0.99   0.99   0.99   0.66   28.7   30.3 -187.2   -1.0
F C G P B SPEED RATIO CUR  PHASE WIND MAXD MNDEV   OUT  DPHASE NPHASE   AZV S
1 Y Y N Y 20000 001/1  80 106.64 0.05 0.00 0.000     0    0.00 106.64 -0.00 P
2 Y Y N Y 20000 001/1  80  98.34 0.05 0.00 0.000     0   -0.00  98.34  0.00 P
3 Y Y N Y 20000 001/1  80 100.25 0.05 0.00 0.000     0    0.00 100.25 -0.00 P
4 Y Y N Y 20000 001/1  80  58.01 0.05 0.00 0.000     0    0.00  58.01  0.00 P
5 Y Y N Y 13333 002/3  80  23.15 0.05 0.00 0.000     0    0.00  23.15 -0.10 P
6 Y Y N Y   831 001/1   0   0.00 0.05 0.00 0.000     0 -181.05 181.05  0.20 C
7 Y Y N Y 20000 001/1  80 172.77 0.05 0.00 0.000     0    0.00 172.77  0.10 P

==SAMPLE ENVIRONMENT==
reading temperature controller...
                                   
sample temperature	= 307.273 K
control temperature	= 198.672 K
setpoint temperature	= 293.0 K
heater power		= 2.3%
heater range choice	= 5.0
Tue May 21 11:26:02 EDT 2013
=====RUNS  QUEUED=====
dry_run version May 2 2012 

TYPE dry_run -? FOR HELP AND OPTIONS

*******************************************************************************
SEQUENCE FILE SELECTED IS /home/NIST/ncnr/sequence.prm
RUNBUF   FILE SELECTED IS /home/NIST/ncnr/runbuf.prm

ZERO START DELAY SELECTED
LISTING BELOW IS FOR SEQUENCE STARTING IMMEDIATELY (Tue May 21 11:26:03 2013) THEN ...

run buffer 1                              done Tue May 21 11:36:37 2013 duration=  10.6 min
run buffer 1                              done Tue May 21 11:47:11 2013 duration=  10.6 min
run buffer 1                              done Tue May 21 11:57:45 2013 duration=  10.6 min
run buffer 1                              done Tue May 21 12:08:19 2013 duration=  10.6 min
run buffer 1                              done Tue May 21 12:18:53 2013 duration=  10.6 min
run buffer 1                              done Tue May 21 12:29:27 2013 duration=  10.6 min
run buffer 1                              done Tue May 21 12:40:01 2013 duration=  10.6 min

-------------------------------------------------------------------------------
>>>>> MESSAGES <<<<<

SEQUENCE FILE /home/NIST/ncnr/sequence.prm SYNTAX    STATUS OK
SEQUENCE FILE /home/NIST/ncnr/sequence.prm PARAMETER STATUS OK

NUMBER OF LINES DEFINED    IN /home/NIST/ncnr/sequence.prm =   7
NUMBER OF LINES RECOGNIZED IN /home/NIST/ncnr/sequence.prm =   7

-------------------------------------------------------------------------------
TOTAL ESTIMATED DURATION OF SEQUENCE =    1.2 hrs
                                     =    0.1 days

**************************************************************************
EASTERN TIME NOW (ACCORDING TO COMPUTER CLOCK) IS Tue May 21 11:26:03 2013
ESTIMATED FINISH TIME IF STARTED IMMEDIATELY   IS Tue May 21 12:40:01 2013
**************************************************************************
Warning: The collimator is not raised. The current position is -26.4999.
Local shutter is closed.